For projects that call for a 40,000 BTU furnace, the YORK TM9Y040A10MP11 pairs a 96% AFUE rating with two-stage (2-Stage) heating. It uses a fixed-speed ECM blower rated at 2.5 tons and has a cabinet listed at 14.5 inches wide, 33 inches high, and 29.5 inches deep. Contractors and property owners can use these specifications to see how this YORK furnace lines up with their system requirements.
BTU, or British Thermal Unit, ratings are a standard way to describe and compare furnace capacity. The YORK TM9Y040A10MP11 is rated at 40,000 BTU, also listed as 40 MBTU. Compare this figure with the heating requirements for your project.
AFUE, or Annual Fuel Utilization Efficiency, measures how much of the fuel energy a furnace turns into usable heat over a typical year. A higher number indicates greater efficiency. This furnace carries a 96% AFUE rating.
Two-stage furnaces can operate at a lower heat output level or a higher one. The lower stage handles milder heating needs, and the higher stage is used when more heat is called for. This furnace is listed as 2-stage.
This furnace is listed as multi-position, so it can be set up for upflow, downflow, or horizontal left or right installation. That flexibility helps installers adapt to the space and ductwork on site.
ECM stands for electronically commutated motor. A fixed-speed ECM blower runs at set speed taps chosen during installation. The blower is rated at 2.5 tons, so confirm that this rating fits the cooling equipment and duct design planned for the system.
The cabinet is listed at 14.5 inches wide, 33 inches high, and 29.5 inches deep. Use these measurements to plan for placement, access, and clearances.
Compare the model number, capacity, efficiency rating, configuration, blower rating, and dimensions listed here with your system requirements before purchasing.
WE SHIP NATIONWIDE ACROSS THE UNITED STATES AND CANADA. SPEAK TO AN EXPERT: 708-400-7000