For split system projects that call for a 60,000 BTU downflow furnace, the RunTru A951X060BD3SA pairs a 96% AFUE rating with single-stage operation. This model uses a multi-speed ECM blower rated at 3.0 tons and has a cabinet listed at 17.5 inches wide, 34 inches high, and 28.75 inches deep. Contractors and property owners can use these specifications to see how this RunTru furnace lines up with their system requirements.
BTU, or British Thermal Unit, ratings are a standard way to describe and compare furnace capacity. The RunTru A951X060BD3SA is rated at 60,000 BTU, also listed as 60 MBTU. Compare this figure with the heating requirements for your project.
AFUE, or Annual Fuel Utilization Efficiency, measures how much of the fuel energy a furnace turns into usable heat over a typical year. A higher number indicates greater efficiency. This furnace carries a 96% AFUE rating.
Single-stage, or 1-stage, heating equipment runs at one fixed output level. It turns on at full output when heat is needed and shuts off once the thermostat setting is reached.
This is a downflow furnace. In a downflow configuration, return air enters at the top of the cabinet and heated air is discharged out the bottom. Confirm that this airflow direction matches the supply and return duct layout on the job.
ECM stands for electronically commutated motor. This furnace uses a multi-speed ECM blower, which means the blower can be set to different speeds. The blower is rated at 3.0 tons, so confirm that this rating fits the cooling equipment and duct design planned for the system.
The cabinet is listed at 17.5 inches wide, 34 inches high, and 28.75 inches deep. Use these measurements to plan for placement, access, and clearances.
Compare the model number, 60,000 BTU capacity, efficiency rating, configuration, blower rating, and dimensions listed here with your system requirements before purchasing.
WE SHIP NATIONWIDE ACROSS THE UNITED STATES AND CANADA. SPEAK TO AN EXPERT: 708-400-7000